WA-WSLD Series Double Head Flooded Water-Cooled Screw Chillers Parameters   (2330KW~3460KW)

WA-WSLD Series Double Head Flooded Water-Cooled Screw Chillers Parameters (2330KW~3460KW)
This series of chiller units incorporates advanced screw technology, integrating high efficiency, stability, and intelligence for medium to large-scale cooling applications. With exceptional engineering design and reliable core components, they deliver consistently efficient and stable performance under various operating conditions, making them an ideal solution for industrial process cooling and comfort air conditioning.
Request for quotation
This series of chiller units incorporates advanced screw technology, integrating high efficiency, stability, and intelligence for medium to large-scale cooling applications. With exceptional engineering design and reliable core components, they deliver consistently efficient and stable performance under various operating conditions, making them an ideal solution for industrial process cooling and comfort air conditioning.


Product Advantages:

● High Efficiency & Quiet Operation: Utilizes semi-hermetic twin-screw compressors for superior efficiency, smooth operation, and significantly reduced noise levels.

● Extended Service Life: High-quality bearings are selected for a design life exceeding 40,000 hours, ensuring long-term reliability.

● Compact Design with Effective Oil Separation: Features a built-in high-efficiency oil separator with a compact structure for optimal oil separation and system stability.

● Precise Modulation & Energy Savings: A multi-stage capacity control system enables smooth and precise load adjustment from 0% to 100%, significantly reducing energy consumption by accurately matching cooling demand.

● Superior Heat Exchange & Flexibility: The evaporator employs a high-efficiency shell and tube heat exchanger with internally enhanced fin tubes for optimized design and outstanding performance. A stainless steel plate heat exchanger is available as an option to suit diverse application requirements.

● Comprehensive Intelligent Control: Equipped with full automatic control functions including startup self-check, intelligent capacity regulation, sequential shutdown, multiple fault protection and diagnosis, operation data logging, status monitoring, and auto-restart, ensuring safe and efficient unit operation.

● User-Friendly Interface: Features a color LCD touch-screen controller with an intuitive interface for easy monitoring of real-time operating status and straightforward operation.

● System Compatibility: Designed to be used with a cooling tower for seamless integration into your cooling system.


WA-WSLD Series Double Head Flooded Water-Cooled Screw Chillers Parameters (2330KW~3460KW)

Items

WA-WSLD2330

WA-WSLD2660

WA-WSLD2984

WA-WSLD3460

Rated cooling capacity

2003800 Kcal/h

2287600 Kcal/h

2566240 Kcal/h

2975600 Kcal/h

662.5USRT

756.3 USRT

848.5 USRT

983.8 USRT

2330KW

2660KW

2984KW

3460KW

Input power

462KW

512KW

570KW

660KW

Max operating current

785.4A

870.4A

969A

1122A

Power

3PH 380V 50HZ (200V /220V/ 415V 50HZ/60HZ)

Refrigerant

Type

R22 /R134A

R22 /R134A

R22 /R134A

R22 /R134A

Control

High-precision digital electronic expansion valve

Compressor

Type

Semi-hermetic screw

Power

462KW

512KW

570KW

660KW

Start

Flexible soft start

Regulation range

0-25-75-100%

Evaporator

Type

High-efficiency falling film

Chilled water flow

400.7m3/h

457.4 m3/h

513.1 m3/h

595 m3/h

Water pressure drop

75Kpa

78Kpa

76Kpa

79Kpa

Inlet/outlet pipe diameter

12” inch

12” inch

12” inch

14” inch

Condenser

Type

Horizontal high efficiency heat exchange shell tube type

Cooling water

480.1 m3/h

545.5 m3/h

611.1 m3/h

708.5 m3/h

Water pressure drop

76Kpa

78Kpa

76Kpa

80Kpa

Inlet/outlet pipe diameter

12” inch

12” inch

12” inch

14” inch

Security protection

Compressor motor overloading protection, compressor bearing overload protection device, intelligent digital high and low pressure protection device, anti - freezing protection device, protection phase - lack digital protection, exhaust temperature protection, over - temperature protection device, safety valve, water flow switch

Dimension & weight

Length

5050mm

5050mm

5050mm

5050mm

Width

2100mm

2150mm

2350mm

2350mm

Height

2330mm

2330mm

2450mm

2450mm

Machine Weight

10865KG

11680KG

12785KG

13730KG

Operating Weight

11665KG

12580KG

13935KG

14640KG


Note:

1. The cooling capacity is based on the inlet temperature of chilled water 12℃, outlet temperature 7℃; The inlet temperature of cooling water inlet 30℃, and the outlet temperature is 35℃.
2. Chilled water temperature range: 5℃ to 30℃;  Cooling water temperature range: 18℃ to 30℃;
3. The above can be customized according to customer requirements.
4. The above specifications are subject to change without prior notice.

Related Suggestion

WA-WSLD Series Double Head Flooded Water-Cooled Screw Chillers Parameters (2330KW~3460KW)
更新时间:Jul 25, 2026
WA-WSLD Series Double Head Flooded Water-Cooled Screw Chillers Parameters   (2330KW~3460KW)
This series of chiller units incorporates advanced screw technology, integrating high efficiency, stability, and intelligence for medium to large-scale cooling applications. With exceptional engineering design and reliable core components, they deliver consistently efficient and stable performance under various operating conditions, making them an ideal solution for industrial process cooling and comfort air conditioning.


Product Advantages:

● High Efficiency & Quiet Operation: Utilizes semi-hermetic twin-screw compressors for superior efficiency, smooth operation, and significantly reduced noise levels.

● Extended Service Life: High-quality bearings are selected for a design life exceeding 40,000 hours, ensuring long-term reliability.

● Compact Design with Effective Oil Separation: Features a built-in high-efficiency oil separator with a compact structure for optimal oil separation and system stability.

● Precise Modulation & Energy Savings: A multi-stage capacity control system enables smooth and precise load adjustment from 0% to 100%, significantly reducing energy consumption by accurately matching cooling demand.

● Superior Heat Exchange & Flexibility: The evaporator employs a high-efficiency shell and tube heat exchanger with internally enhanced fin tubes for optimized design and outstanding performance. A stainless steel plate heat exchanger is available as an option to suit diverse application requirements.

● Comprehensive Intelligent Control: Equipped with full automatic control functions including startup self-check, intelligent capacity regulation, sequential shutdown, multiple fault protection and diagnosis, operation data logging, status monitoring, and auto-restart, ensuring safe and efficient unit operation.

● User-Friendly Interface: Features a color LCD touch-screen controller with an intuitive interface for easy monitoring of real-time operating status and straightforward operation.

● System Compatibility: Designed to be used with a cooling tower for seamless integration into your cooling system.


WA-WSLD Series Double Head Flooded Water-Cooled Screw Chillers Parameters (2330KW~3460KW)

Items

WA-WSLD2330

WA-WSLD2660

WA-WSLD2984

WA-WSLD3460

Rated cooling capacity

2003800 Kcal/h

2287600 Kcal/h

2566240 Kcal/h

2975600 Kcal/h

662.5USRT

756.3 USRT

848.5 USRT

983.8 USRT

2330KW

2660KW

2984KW

3460KW

Input power

462KW

512KW

570KW

660KW

Max operating current

785.4A

870.4A

969A

1122A

Power

3PH 380V 50HZ (200V /220V/ 415V 50HZ/60HZ)

Refrigerant

Type

R22 /R134A

R22 /R134A

R22 /R134A

R22 /R134A

Control

High-precision digital electronic expansion valve

Compressor

Type

Semi-hermetic screw

Power

462KW

512KW

570KW

660KW

Start

Flexible soft start

Regulation range

0-25-75-100%

Evaporator

Type

High-efficiency falling film

Chilled water flow

400.7m3/h

457.4 m3/h

513.1 m3/h

595 m3/h

Water pressure drop

75Kpa

78Kpa

76Kpa

79Kpa

Inlet/outlet pipe diameter

12” inch

12” inch

12” inch

14” inch

Condenser

Type

Horizontal high efficiency heat exchange shell tube type

Cooling water

480.1 m3/h

545.5 m3/h

611.1 m3/h

708.5 m3/h

Water pressure drop

76Kpa

78Kpa

76Kpa

80Kpa

Inlet/outlet pipe diameter

12” inch

12” inch

12” inch

14” inch

Security protection

Compressor motor overloading protection, compressor bearing overload protection device, intelligent digital high and low pressure protection device, anti - freezing protection device, protection phase - lack digital protection, exhaust temperature protection, over - temperature protection device, safety valve, water flow switch

Dimension & weight

Length

5050mm

5050mm

5050mm

5050mm

Width

2100mm

2150mm

2350mm

2350mm

Height

2330mm

2330mm

2450mm

2450mm

Machine Weight

10865KG

11680KG

12785KG

13730KG

Operating Weight

11665KG

12580KG

13935KG

14640KG


Note:

1. The cooling capacity is based on the inlet temperature of chilled water 12℃, outlet temperature 7℃; The inlet temperature of cooling water inlet 30℃, and the outlet temperature is 35℃.
2. Chilled water temperature range: 5℃ to 30℃;  Cooling water temperature range: 18℃ to 30℃;
3. The above can be customized according to customer requirements.
4. The above specifications are subject to change without prior notice.

在线咨询

Submit

相关推荐