In-Row Precision Air Conditioner, also known as row-based cooling unit, is a close-coupled precision cooling device dedicated to high-density data centers and modular computer rooms. Installed vertically between rows of IT server racks, it adopts a horizontal front-supply & rear-return air circulation layout. Different from traditional room-level CRAC units with long-distance air delivery, it sends cold air directly to server inlets to cut airflow path drastically. Matched with hot & cold aisle containment systems, it fundamentally eliminates air mixing, short-circuit airflow and rack hotspots, delivering uniform, stable temperature & humidity control for all IT racks. It has become the mainstream energy-saving thermal management solution for cloud computing, AI computing rooms and pod-based modular data centers.


Advantages

● Close-Coupled High-Efficiency Cooling, Zero Hotspots

Cooling right next to heat sources with only 1~2m airflow distance to avoid cooling loss. Perfect for high-density IT loads over 5kW per rack, preventing overheating & downtime of AI servers and blade servers.

● Ultra-High Energy Efficiency, Lower Data Center PUE

Equipped with variable frequency compressors, EC energy-saving fans and electronic expansion valves for stepless cooling regulation. High sensible heat ratio minimizes unnecessary dehumidification. Optional refrigerant pump free cooling module enables free natural cooling in winter & transition seasons, lowering overall PUE below 1.2.

● Flexible Installation, No Raised Floor Required

Horizontal air circulation works without raised access floors, ideal for legacy room retrofits, containerized pods and single-story simple server rooms. Standard rack-matching dimensions allow seamless side-by-side installation with IT cabinets.

● All-Weather Intelligent Group Control

Supports standalone operation and N+1 redundant cluster linkage. Built-in DCIM communication interface enables remote real-time monitoring of temperature, humidity, air pressure and unit status, with auto fault alarm and intelligent load balancing.

● Easy Maintenance & Outstanding Reliability

Hot-swappable fans for replacement without shutdown; dual condensate drain pans prevent water leakage. Designed for non-stop 24/7/365 operation, fully compliant with strict Tier III/IV data center operation standards.


Application Scenario

● Large & medium cloud data centers, AI computing rooms, supercomputing facilities

● Single-row, double-row & double-decker containerized modular pods

● Telecom base station equipment rooms, enterprise core server rooms

● High-density network rack rooms & thermal retrofitting projects for legacy computer rooms